浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司,采用硅烷化玻璃微珠總烴柱+13X分子篩甲烷柱建立氣相色譜法測(cè)定固定污染源廢氣/環(huán)境空氣中非甲烷總烴的方法。通過(guò)校準(zhǔn)曲線、空白實(shí)驗(yàn)、檢出限、樣品穩(wěn)定性實(shí)驗(yàn)、正確度和精密度的驗(yàn)證,該方法校準(zhǔn)曲線的相關(guān)系數(shù)大于0.999 5檢出限為0.03?mg/m3,低、中、高濃度標(biāo)準(zhǔn)氣體的測(cè)定結(jié)果相對(duì)誤差不大于3.00%,相對(duì)標(biāo)準(zhǔn)偏差不大于5.00%。該方法具有檢出限低、準(zhǔn)確度好,經(jīng)實(shí)際樣品檢測(cè)分析后表明該方法適用于固定污染源廢氣/環(huán)境空氣中非甲烷總烴的測(cè)定。
?
名稱:硅烷化玻璃微珠總烴柱
規(guī)格:1m*3mm,60-80目
型號(hào):HH-BLQ
編號(hào):20241101002
*高使用溫度:300°C
應(yīng)用:HJ2017固定污染源廢氣中總烴,甲烷,非甲烷總烴的測(cè)定 氣相色譜法
環(huán)境空氣中總烴,甲烷,非甲烷總烴的測(cè)定 氣相色譜法HJ2017
名稱:13X分子篩甲烷柱
規(guī)格:1m*3mm,60-80Mesh
*高使用溫度:320°C
編號(hào):20241101003
應(yīng)用“”:安捷倫6890,7820,7890,8860,8890;島津GC2010,GC-2014,GC-2018,GC-2030,賽默飛,瓦里安,布魯克,PE
分離:
1.HJ3017/1999固定污染源廢氣中總烴,甲烷,非甲烷總烴的測(cè)定? 氣相色譜法
2.環(huán)境空氣中總烴,甲烷,非甲烷總烴的測(cè)定? 氣相色譜法
氧與甲烷分離完全,無(wú)干擾
?
?
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. established a gas chromatography method for the determination of non methane total hydrocarbons in fixed pollution source exhaust gas/ambient air using a silanized glass bead total hydrocarbon column+13X molecular sieve methane column. Through calibration curve, blank experiment, detection limit, sample stability experiment, accuracy and precision verification, the correlation coefficient of the calibration curve of this method is greater than 0.999. The detection limit is 0.03 mg/m3, and the relative error of the determination results of low, medium and high concentration standard gases is not greater than 3.00%, and the relative standard deviation is not greater than 5.00%. This method has low detection limit and good accuracy. After actual sample analysis, it has been shown that this method is suitable for the determination of non methane total hydrocarbons in fixed pollution source exhaust gas/ambient air.
Name: Silanized Glass Bead Total Hydrocarbon Column
Specification: 1m * 3mm, 60-80 mesh
Model: HH-BLQ
Number: 20241101002
*High operating temperature: 300 ° C
Application: HJ2017 Determination of Total Hydrocarbons, Methane, and Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources Gas Chromatography Method
Determination of total hydrocarbons, methane, and non methane total hydrocarbons in ambient air by gas chromatography HJ2017
Name: 13X Molecular Sieve Methane Column
Specification: 1m * 3mm, 60-80Mesh
*High operating temperature: 320 ° C
Number: 20241101003
Application: Agilent 689078207890886088890; Shimadzu GC2010, GC-2014, GC-2018, GC-2030, Thermo Fisher, Varian, Brooke, PE
Separation:
HJ3017/1999 Determination of Total Hydrocarbons, Methane, and Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources Gas Chromatography Method
2. Determination of total hydrocarbons, methane, and non methane total hydrocarbons in ambient air by gas chromatography
Complete separation of oxygen and methane without interference