固定污染源廢氣的采樣應(yīng)符合中的相關(guān)規(guī)定。采樣時(shí)敲開(kāi)活性炭采樣管的兩端,與煙氣采樣器相連(A段為氣體入口),檢查采樣系統(tǒng)的氣密性,檢查方法和標(biāo)準(zhǔn)按照HJ/T 397要求執(zhí)行。以0.2 L/min~1.0 L/min的采樣流量,連續(xù)采樣1 h,或在1 h內(nèi)以等時(shí)間間隔采集3~4個(gè)樣品計(jì)平均值,采樣時(shí)間一般不少于10 min。若廢氣中濕度太大,以致在活性炭管中凝結(jié)時(shí),必須在煙氣采樣槍和活性炭采樣管之間加裝除濕裝置,并伴熱以除去水汽對(duì)活性炭采樣管的影響。
本標(biāo)準(zhǔn)規(guī)定了環(huán)境空氣和廢氣中三甲苯(1,3,5-三甲苯、1,2,4-三甲苯和1,2,3-三甲苯)測(cè)定的活性炭吸附/二硫化碳解吸-氣相色譜法。
本標(biāo)準(zhǔn)適用于環(huán)境空氣以及木質(zhì)家具制造業(yè)、汽車(chē)制造和維修業(yè)等有組織和無(wú)組織排放廢氣中三甲苯的測(cè)定,其他行業(yè)廢氣經(jīng)驗(yàn)證后也可使用本方法。
對(duì)于環(huán)境空氣,當(dāng)采樣體積為30 L時(shí),本方法檢出限為0.004 mg/m3~0.006 mg/m3,測(cè)定下限為0.016 mg/m3~0.024 mg/m3;對(duì)于廢氣,當(dāng)采樣體積為10 L時(shí),本方法檢出限均為0.02 mg/m3,測(cè)定下限均為0.08 mg/m3,詳見(jiàn)附錄A。
名稱:聚乙二醇毛細(xì)管柱
型號(hào):PEG-20M
規(guī)格:30m*0.32mm*1.0um
溫度:240°C
The sampling of exhaust gas from fixed pollution sources should comply with the relevant regulations in. When sampling, open both ends of the activated carbon sampling tube and connect it to the flue gas sampler (section A is the gas inlet) to check the airtightness of the sampling system. The inspection method and standard should be carried out in accordance with the requirements of HJ/T 397. Sample continuously for 1 hour at a sampling flow rate of 0.2 L/min to 1.0 L/min, or collect 3-4 samples at equal time intervals within 1 hour to calculate the average value. The sampling time is generally not less than 10 minutes. If the humidity in the exhaust gas is too high to condense in the activated carbon tube, a dehumidification device must be installed between the flue gas sampling gun and the activated carbon sampling tube, and heat tracing must be carried out to remove the influence of water vapor on the activated carbon sampling tube.
This standard specifies the activated carbon adsorption/Carbon disulfide desorption gas chromatography method for the determination of trimethylene (1,3,5-trimethylene, 1,2,4-trimethylene and 1,2,3-trimethylene) in ambient air and waste gas.
This standard is applicable to the determination of trimethylbenzene in environmental air, as well as in organized and unorganized exhaust gases from wood furniture manufacturing, automotive manufacturing, and maintenance industries. This method can also be used after verification in other industries' exhaust gases.
For ambient air, when the sampling volume is 30 L, the detection limit of this method is 0.004 mg/m3 to 0.006 mg/m3, and the detection limit is 0.016 mg/m3 to 0.024 mg/m3; For exhaust gas, when the sampling volume is 10 L, the detection limit of this method is 0.02 mg/m3, and the lower limit of determination is 0.08 mg/m3. Please refer to Appendix A.
Name: Polyethylene glycol capillary column
Model: PEG-20M
Specification: 30m * 0.32mm * 1.0um
Temperature: 240 ° C
滕州市浩瀚色譜儀器技術(shù)服務(wù)有限公司
電話:0632-5667636
傳真:0632-5667636
手機(jī):15562228838,13963221227
地址:山東滕州市平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
聯(lián)系人:王經(jīng)理
網(wǎng)址:tuoliao8.cn